Gas and Process Sample Transport Systems for Analyzer Applications
















Insulation materials must be chosen for the application. Considerations include chloride content, wicking, temperature range and mechanical stability.


The insulations used in TRACEPAK tubing bundles virtually eliminate the wicking problem. They also have low water soluble chloride content, averaging below 30ppm.

Standard

Type DE glass fiber with resin binder

  • k @ 400°F = 0.056

  • Maximum temperature 500°F

  • Organic Binder

  • Soluble Chlorides average less than 30 ppm

High Temperature

Woven Type DE glass fiber

  • k @ 400°F = 0.058

  • Maximum temperature 1200°F

  • Mechanical binder - woven

  • Soluble Chlorides average less than 30 ppm

 

 

Integrated Solutions Improving Process Accuracy

©2003 O'Brien Corporation